Add Your Heading Text Here

$1,250.00

Standard tier. Rated 800 sq ft coverage with a Thermal Efficiency of 97 and fixed-output operation. Listed as a representative configuration for comparing options within Radiant Heating Systems.

Before you buy. The capacity shown is one point in this category’s range, not a recommendation for your building. Equipment must be selected from a Manual J load calculation, the certified rating for the exact matched system should be verified in the AHRI or HVI directory, and installation must be carried out by a licensed HVAC contractor.

SKU HVP-HEA0404-02 Category Tags ,

Overview

This standard-tier radiant wall heating is rated at 800 sq ft coverage and sits in the Radiant Heating Systems range within HVACPool’s Heating section. It is listed here as a representative configuration so buyers can compare capacity, efficiency and staging across the category before shortlisting specific manufacturer models.

Key Specifications

  • Rated capacity: 800 sq ft coverage
  • Thermal Efficiency (%): 97
  • Staging: Single-Stage
  • Energy source: Electric

What to Compare in This Category

When you weigh one unit in this category against another, these are the factors that decide it:

  • Surface temperature
  • wall area
  • controls
  • furniture restrictions
  • installation cost
  • comfort uniformity

Sizing

Capacity must come from a Manual J load calculation for the building, not from floor area alone. An oversized unit short-cycles, leaves humidity in the air and wears its components faster; an undersized one runs continuously and still misses setpoint on design days. Treat the 800 sq ft coverage figure above as one point on the range this category covers, not as a recommendation for your home.

Installation and Maintenance

Installation quality has more effect on delivered performance than the difference between two nameplate efficiency ratings. Confirm venting, clearances, refrigerant charge or water temperature, and duct or line-set design with a licensed contractor before purchase.

Verify Before You Buy

Check the certified rating for the exact model number in the AHRI or HVI directory, and confirm current ENERGY STAR status on energystar.gov. Ratings quoted in marketing material often apply to a specific indoor/outdoor combination rather than the outdoor unit alone.

Reference: https://www.energy.gov/cmei/buildings/articles/building-energy-modeling-101-hvac-design-and-operation-use-case

Weight 30.9 lbs